Features |
1.High reliability due to bifurcated contacts
2.Surge voltage 1,500V according to FCC part68
3.Dielectric strength 1,000V between same pole contacts
4.DIL pitch terminal
5.Perfectly sealed package construction
|
Applications |
1.Telecommunication network equipment
2.Microcomputer system
3.Measurement and control
4.Entertainment and medical equipment
|
Dimensions (mm) |
To convert into inches, multiply by 0.03937
|
|
|
PC Board Layout |
Copper-side view
|
Schematic |
Copper-side view
|
|
Contact data |
| Contact data |
| Arrangement |
2 Form C (DPDT) |
| Contact material |
Gold clad alloy |
| Initial contact resistance |
50m§Ù max. |
| Rated load, resistive |
1A 24VDC 1A 120VAC |
| Maximum switching current |
2A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
60W 120VA |
| Maximum switching voltage |
220VDC 250VAC |
| Minimum switching rating 1) |
1mA 5VDC |
1) Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test
with the actual load before production since reference values may vary according to switching frequencies, environmental
conditions and expected reliability levels.
|
|
Contact data |
| Coil data |
| Nominal voltage |
3VDC to 48VDC |
| Nominal power consumption 2) |
200mW, 360mW |
| Operate voltage 3) |
75% of nominal voltage |
| Release voltage 4) |
10% of nominal voltage |
|
2), 3), 4)The values depend on coil voltage, see Part selection chart
|
|
General data |
| Contact data |
| Operate time |
6ms max. at nominal voltage |
| Release time |
4ms max. at nominal voltage |
| Initial insulation resistance |
100 M min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000VACrms for 1 minute 1,000VACrms for 1 minute |
| Surge strength |
Between contacts & coil: |
1,500V (according to FCC part68) |
| Expected life |
Mechanical: Electrical: |
More than 100,000,000 operations More than 100,000 operations at rated load |
| Vibration resistance |
Functional: Destructive: |
10~55Hz dual amplitude: 1.5mm 10~55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£40¡É to 70¡É (with no icing) |
| Humidity |
45% to 85% RH |
| Weight |
5g approx. |
|
Note: The above figures are initial values
|
|
Part number description |
Part number description is provided for reference, part number can not be arbitrarily composed. Refer to the part numbers
shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
Part selection |
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC) |
Max voltage (VDC) |
Nominal power (mW) |
| Standard coil |
| HR90 DC03 |
3 |
25 |
120 |
2.25 |
0.3 |
3.3 |
360 |
| HR90 DC05 |
5 |
70 |
71.4 |
3.75 |
0.5 |
5.5 |
| HR90 DC06 |
6 |
100 |
60.0 |
4.50 |
0.6 |
6.6 |
| HR90 DC09 |
9 |
225 |
40.0 |
6.75 |
0.9 |
9.9 |
| HR90 DC12 |
12 |
400 |
30.0 |
9.00 |
1.2 |
13.2 |
| HR90 DC24 |
24 |
1,600 |
15.0 |
18.0 |
2.4 |
26.4 |
| HR90 DC48* |
48 |
5,760 |
8.3 |
36.0 |
4.8 |
52.8 |
400 |
| Sensitive coil |
| HR90 DC03-H |
3 |
45 |
66.7 |
2.25 |
0.3 |
3.3 |
200 |
| HR90 DC05-H |
5 |
125 |
40.0 |
3.75 |
0.5 |
5.5 |
| HR90 DC06-H |
6 |
180 |
33.3 |
4.50 |
0.6 |
6.6 |
| HR90 DC09-H |
9 |
400 |
22.5 |
6.75 |
0.9 |
9.9 |
| HR90 DC12-H |
12 |
700 |
17.1 |
9.00 |
1.2 |
13.2 |
| HR90 DC24-H |
24 |
2,800 |
8.57 |
18.0 |
2.4 |
26.4 |
|
|
 |
|