Features |
1.Low power consumption, 150mW
2.1,500V Surge strength conforms to FCC part68
3.Basic grid (one inch) terminal layout
4.Immersion cleanable, sealed type
|
Applications |
1.Telecommunication systems
2.Computer peripherals
3.Audio, Portable, Security equipments
|
Dimensions (mm) |
To convert into inches, multiply by 0.03937
|
PC Board Layout |
Copper-side view
|
Schematic |
Copper-side view
|
|
|
|
Contact data |
| Contact data |
| Arrangement |
1 Form C (SPDT) |
| Contact material |
AuAg Alloy |
| Initial contact resistance |
100m§Ù max. |
| Rated load, resistive |
1A 24VDC 0.5A 125VAC |
| Maximum switching current |
2A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
30W 62.5VA |
| Maximum switching voltage |
60VDC 125VAC |
| Minimum switching rating 1) |
1mA 5VDC |
1)
Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test
with the actual load before production since reference values may vary according to switching frequencies, environmental
conditions and expected reliability levels.
|
|
Coil data |
| Coil data |
| Nominal voltage |
3VDC to 24VDC |
| Nominal power consumption 2) |
150mW , 200mW |
| Operate voltage 3) |
80% of nominal voltage |
| Release voltage 4) |
10% of nominal voltage |
|
2), 3), 4)The values depend on coil voltage, see Part selection chart
|
|
General data |
| Contact data |
| Operate time |
5ms max. at nominal voltage |
| Release time |
5ms max. at nominal voltage |
| Initial insulation resistance |
1,000 M min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
500VACrms for 1 minute 1,000VACrms for 1 minute |
| Surge strength |
Between contacts & coil: |
1,500V (according to FCC part68) |
| Expected life |
Mechanical: Electrical: |
More than 5,000,000 operations More than 100,000 operations at rated load |
| Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.5mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£30¡É to £«70¡É (with no icing) |
| Humidity |
35% to 85% RH |
| Weight |
2.2g approx. |
|
Note: The above figures are initial values
|
|
Part number description |
Part number description is provided for reference, part number can not be arbitrarily composed. Refer to the part numbers
shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
Part selection |
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC) |
Max voltage (VDC) |
Nominal power (mW) |
| Standard coil |
| HR90 DC03 |
3 |
45 |
66.7 |
2.4 |
0.3 |
3.3 |
200 |
| HR90 DC05 |
5 |
125 |
40.0 |
4.0 |
0.5 |
5.5 |
| HR90 DC06 |
6 |
180 |
33.3 |
4.8 |
0.6 |
6.6 |
| HR90 DC09 |
9 |
405 |
22.2 |
7.2 |
0.9 |
9.9 |
| HR90 DC12 |
12 |
720 |
16.7 |
9.6 |
1.2 |
13.2 |
| HR90 DC24 |
24 |
2,880 |
8.3 |
19.2 |
2.4 |
26.4 |
| Sensitive coil |
| HR90 DC03-H |
3 |
60 |
50.0 |
2.4 |
0.3 |
3.3 |
150 |
| HR90 DC05-H |
5 |
167 |
30.0 |
4.0 |
0.5 |
5.5 |
| HR90 DC06-H |
6 |
240 |
25.0 |
4.8 |
0.6 |
6.6 |
| HR90 DC09-H |
9 |
540 |
16.7 |
7.2 |
0.9 |
9.9 |
| HR90 DC12-H |
12 |
960 |
12.5 |
9.6 |
1.2 |
13.2 |
| HR90 DC24-H |
24 |
3,840 |
6.25 |
19.2 |
2.4 |
26.4 |
|
|
|
 |
|