Features
1.Gold overlay contacts, superior reliability (F type)
2.Basic grid (one inch) terminal layout
3.FCC part68 surge strength 1,500V (F type)
Applications
1.Telecommunication
2.Office machines
3.Vending machines
4.Audio equipments
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact data
Arrangement 1 Form C (SPDT)
Contact material Au-clad Ag
Initial contact resistance 100m§Ù max.
Rated load, resistive 1A 24VDC
1A 120VAC
Maximum switching current 2A
Maximum switching
capacity
with DC voltage:
with AC voltage:
30W
120VA
Maximum switching voltage 60VDC
125VAC
Minimum switching rating 1) 1mA 5VDC
1) Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test
with the actual load before production since reference values may vary according to switching frequencies, environmental
conditions and expected reliability levels.
Coil data
Coil data
Nominal voltage 3VDC to 24VDC
Nominal power consumption 2) 200mW , 450mW
Operate voltage 3) Standard coil:
Sensitive coil:
70% of nominal voltage
80% of nominal voltage
Release voltage 4) 10% of nominal voltage
2), 3), 4)The values depend on coil voltage, see Part selection chart
General data
Contact data
Operate time 5ms max. at nominal voltage
Release time 5ms max. at nominal voltage
Initial insulation resistance 100 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
500VACrms for 1 minute
Double movable terminal type :
500VACrms for 1 minute
Single movable terminal type:
1,000VACrms for 1 minute
Surge strength Between contacts & coil: 1,500V (single movable terminal type)
Expected life Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated load
Vibration resistance Functional:
Destructive:
110¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature £­25¡É to £«55¡É (with no icing)
Humidity 35% to 85% RH
Weight 4g approx.
Note: The above figures are initial values
Part number description
Part number description is provided for reference, part number can not be arbitrarily composed. Refer to the part numbers
shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part selection
Part number Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC
)
Max
voltage
(VDC)
Nominal
power
(mW)
Double movable terminal, Standard coil
HR90 DC03 3 20 150 2.1 0.3 3.3 450
HR90 DC05 5 56 90 3.5 0.5 5.5
HR90 DC06 6 80 75 4.2 0.6 6.6
HR90 DC09 9 180 50 6.3 0.9 9.9
HR90 DC12 12 320 37.5 8.4 1.2 13.2
HR90 DC24 24 1,280 18.75 16.8 2.4 26.4
SDouble movable terminal, Sensitive coil
HR90 DC03-H 3 45 66.6 2.4 0.3 3.3 200
HR90 DC05-H 5 125 40.0 4.0 0.5 5.5
HR90 DC06-H 6 180 33.3 4.8 0.6 6.6
HR90 DC09-H 9 400 22.5 7.2 0.9 9.9
HR90 DC12-H 12 720 16.6 9.6 1.2 13.2
HR90 DC24-H 24 2,880 8.3 19.2 2.4 26.4