1.High electrical noise immunity
2.Up to 10A switching capacity in a compact package
3.Dielectric strength 4,000V, surge strength 8,000V
4.Sensitive 200mW and standard 450mW available
1.Home appliance, Industrial control
To convert into inches, multiply by 0.03937
Copper-side view
Copper-side view
Contact data
Arrangement 1 Form A (SPST) 1 Form C (SPDT)
Contact material Ag Alloy
Initial contact resistance 100m§Ù max.
Rated load, resistive 5A 30VDC
10A 125VAC
5A 250VAC
NO
NC
5A 30VDC
10A
125VAC
5A 250VAC
3A 30VDC
5A 125VAC
3A 250VAC
Maximum switching current 10A 10A 5A
Maximum
switching
capacity
with DC voltage:
with AC voltage:
150W
1,250VA
150W
1,250VA
90W
750VA
Maximum switching voltage 110VDC
250VAC
Coil data
Nominal voltage 3VDC to 24VDC
Nominal power consumption 1) 200mW, 450mW
Operate voltage 2) 75% of nominal voltage
Release voltage 3) 5% of nominal voltage
1), 2), 3)The values depend on coil voltage, see Part selection chart
General data
Operate time 8ms max. at nominal voltage
Release time 5ms max. at nominal voltage
Initial insulation resistance 1,000 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
1,000VACrms for 1 minute
4,000VACrms for 1 minute
Surge strength Between contacts &
coil:
8,000V
Expected life Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated
load
Vibration
resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature £­40¡É to £«70¡É (with no icing)
Humidity 35% to 85% RH
Weight 6g approx.
Note: The above figures are initial values
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part number Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
)
Max
voltage
(VDC)
Nominal
power
(mW)
Standard coil, 1 Form A
HR96A 03 3 20 150 2.25 0.15 3.9 450
HR96A 05 5 56 90 3.75 0.25 5.5
HR96A 06 6 80 75 4.50 0.30 6.6
HR96A 09 9 180 50 6.75 0.45 9.9
HR96A 12 12 320 37.5 9.00 0.60 13.2
HR96A 18 18 720 25 13.5 0.90 19.8
HR96A 24 24 1,280 18.75 18.0 1.20 26.4
Sensitive coil, 1 Form A
HR96A 03H 3 45 66.7 2.25 0.15 3.3 200
HR96A 05H 5 125 40.0 3.75 0.25 5.5
HR96A 06H 6 180 33.3 4.50 0.3 6.6
HR96A 09H 9 400 22.5 6.75 0.45 9.9
HR96A 12H 12 720 16.7 9.00 0.60 13.2
HR96A 18H 18 1,600 11.2 13.5 0.90 19.8
HR96A 24H 24 2,800 8.57 18.0 1.2 26.4
Standard coil, 1 Form C
HR96C 03 3 20 150 2.25 0.15 3.9 450
HR96C 05 5 56 90 3.75 0.25 5.5
HR96C 06 6 80 75 4.50 0.30 6.6
HR96C 09 9 180 50 6.75 0.45 9.9
HR96C 12 12 320 37.5 9.00 0.6 13.2
HR96C 18 18 720 25 13.5 0.90 19.8
HR96C 24 24 1,280 18.75 18.0 1.20 26.4
Sensitive coil, 1 Form C
HR96C 03H 3 45 66.7 2.25 0.15 3.3 200
HR96C 05H 5 125 40.0 3.75 0.25 5.5
HR96C 06H 6 180 33.3 4.50 0.30 6.6
HR96C 09H 9 400 22.5 6.75 0.45 9.9
HR96C 12H 12 720 16.7 9.00 0.6 13.2
HR96C 18H 18 1,600 11.2 13.5 0.9 19.8
HR96C 24H 24 2,800 8.57 18.0 1.2 26.4
Note: All values in the chart are measured at 23¡É