1.High electrical noise immunity
2.Up to 10A switching capacity in a compact package
3.Dielectric strength 4,000V, surge strength 8,000V
4.Sensitive 200mW and standard 450mW available
|
|
 |
|
1.Home appliance, Industrial control
|
|
 |
| To convert into inches, multiply by 0.03937 |
|
|
|
 |
Copper-side view
|
 |
Copper-side view
|
|
|
|
| Contact data |
| Arrangement |
1 Form A (SPST) |
1 Form C (SPDT) |
| Contact material |
Ag Alloy |
| Initial contact resistance |
100m§Ù max. |
| Rated load, resistive |
5A 30VDC 10A 125VAC 5A 250VAC |
NO |
NC
|
5A 30VDC 10A 125VAC 5A 250VAC |
3A 30VDC 5A 125VAC 3A 250VAC |
| Maximum switching current |
10A |
10A |
5A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
150W 1,250VA |
150W 1,250VA |
90W 750VA |
| Maximum switching voltage |
110VDC 250VAC |
| Coil data |
| Nominal voltage |
3VDC to 24VDC |
| Nominal power consumption 1) |
200mW, 450mW |
| Operate voltage 2) |
75% of nominal voltage |
| Release voltage 3) |
5% of nominal voltage |
|
1), 2), 3)The values depend on coil voltage, see Part selection chart
|
|
| General data |
| Operate time |
8ms max. at nominal voltage |
| Release time |
5ms max. at nominal voltage |
| Initial insulation resistance |
1,000 M§Ù min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000VACrms for 1 minute 4,000VACrms for 1 minute |
| Surge strength |
Between contacts & coil: |
8,000V |
| Expected life |
Mechanical: Electrical: |
More than 10,000,000 operations More than 100,000 operations at rated load |
Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.5mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£40¡É to £«70¡É (with no icing) |
| Humidity |
35% to 85% RH |
| Weight |
6g approx. |
|
Note: The above figures are initial values
|
|
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
 |
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC)) |
Max voltage (VDC) |
Nominal power (mW) |
| Standard coil, 1 Form A |
| HR96A 03 |
3 |
20 |
150 |
2.25 |
0.15 |
3.9 |
450 |
| HR96A 05 |
5 |
56 |
90 |
3.75 |
0.25 |
5.5 |
| HR96A 06 |
6 |
80 |
75 |
4.50 |
0.30 |
6.6 |
| HR96A 09 |
9 |
180 |
50 |
6.75 |
0.45 |
9.9 |
| HR96A 12 |
12 |
320 |
37.5 |
9.00 |
0.60 |
13.2 |
| HR96A 18 |
18 |
720 |
25 |
13.5 |
0.90 |
19.8 |
| HR96A 24 |
24 |
1,280 |
18.75 |
18.0 |
1.20 |
26.4 |
| Sensitive coil, 1 Form A |
| HR96A 03H |
3 |
45 |
66.7 |
2.25 |
0.15 |
3.3 |
200 |
| HR96A 05H |
5 |
125 |
40.0 |
3.75 |
0.25 |
5.5 |
| HR96A 06H |
6 |
180 |
33.3 |
4.50 |
0.3 |
6.6 |
| HR96A 09H |
9 |
400 |
22.5 |
6.75 |
0.45 |
9.9 |
| HR96A 12H |
12 |
720 |
16.7 |
9.00 |
0.60 |
13.2 |
| HR96A 18H |
18 |
1,600 |
11.2 |
13.5 |
0.90 |
19.8 |
| HR96A 24H |
24 |
2,800 |
8.57 |
18.0 |
1.2 |
26.4 |
| Standard coil, 1 Form C |
| HR96C 03 |
3 |
20 |
150 |
2.25 |
0.15 |
3.9 |
450 |
| HR96C 05 |
5 |
56 |
90 |
3.75 |
0.25 |
5.5 |
| HR96C 06 |
6 |
80 |
75 |
4.50 |
0.30 |
6.6 |
| HR96C 09 |
9 |
180 |
50 |
6.75 |
0.45 |
9.9 |
| HR96C 12 |
12 |
320 |
37.5 |
9.00 |
0.6 |
13.2 |
| HR96C 18 |
18 |
720 |
25 |
13.5 |
0.90 |
19.8 |
| HR96C 24 |
24 |
1,280 |
18.75 |
18.0 |
1.20 |
26.4 |
| Sensitive coil, 1 Form C |
| HR96C 03H |
3 |
45 |
66.7 |
2.25 |
0.15 |
3.3 |
200 |
| HR96C 05H |
5 |
125 |
40.0 |
3.75 |
0.25 |
5.5 |
| HR96C 06H |
6 |
180 |
33.3 |
4.50 |
0.30 |
6.6 |
| HR96C 09H |
9 |
400 |
22.5 |
6.75 |
0.45 |
9.9 |
| HR96C 12H |
12 |
720 |
16.7 |
9.00 |
0.6 |
13.2 |
| HR96C 18H |
18 |
1,600 |
11.2 |
13.5 |
0.9 |
19.8 |
| HR96C 24H |
24 |
2,800 |
8.57 |
18.0 |
1.2 |
26.4 |
|
|
Note: All values in the chart are measured at 23¡É
|
|
|
|
|
 |
|