1.Universal size and foot print
2.Highest carry current capability of its kind, 15A
3.Design conforms to various safety standard
4.Sealed construction standard
|
|
 |
|
1.Home appliance, Office equipment,
Vending machine, Industrial control
|
|
|
|
|
 |
| To convert into inches, multiply by 0.03937 |
 |
 |
Copper-side view
|
 |
Copper-side view
|
|
|
|
| Contact data |
| Arrangement |
1 Form A (SPST) to 1 Form C (SPDT) |
| Contact material |
AgCdO |
| Initial contact resistance |
100m§Ù max. |
| Rated load, resistive |
12A 24VDC 12A 120VAC 10A 250VAC |
| Maximum switching current |
15A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
240W 2,500VA |
| Maximum switching voltage |
110VDC 250VAC |
| Coil data |
| Nominal voltage |
3VDC to 48VDC |
| Nominal power consumption 1) |
360mW |
| Operate voltage 2) |
75% of nominal voltage |
| Release voltage 3) |
10% of nominal voltage |
|
1), 2), 3)The values depend on coil voltage, see Part selection chart
|
|
| General data |
| Operate time |
10ms max. at nominal voltage |
| Release time |
5ms max. at nominal voltage |
| Initial insulation resistance |
1,00 M§Ù min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000VACrms for 1 minute 2,500VACrms for 1 minute |
| Expected life |
Mechanical: Electrical: |
More than 10,000,000 operations More than 100,000 operations at rated load |
Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.5mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Heating Cold |
+80¡¾2¡É 1000hrs -40¡¾2¡É 1000hrs |
| Humidity |
35% to 85% RH |
| Weight |
9.5g approx. |
|
Note: The above figures are initial values
|
|
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC)) |
Max voltage (VDC) |
Nominal power (mW) |
| 1 Form A |
| HR703HA DC03V |
3 |
25 |
120 |
2.25 |
0.3 |
3.9 |
360 |
| HR703HA DC05V |
5 |
70 |
72 |
3.75 |
0.5 |
6.5 |
| HR703HA DC06V |
6 |
100 |
60 |
4.5 |
0.6 |
7.8 |
| HR703HA DC09V |
9 |
225 |
40 |
6.75 |
0.9 |
11.7 |
| HR703HA DC12V |
12 |
400 |
30 |
9.00 |
1.2 |
15.6 |
| HR703HA DC24V |
24 |
1,600 |
15 |
18.00 |
2.4 |
31.2 |
| HR703HA DC48V |
48 |
6,400 |
7.5 |
36.00 |
4.8 |
62.4 |
| 1 Form C |
| HR703H DC03V |
3 |
25 |
120 |
2.25 |
0.3 |
3.9 |
360 |
| HR703H DC05V |
5 |
70 |
72 |
3.75 |
0.5 |
6.5 |
| HR703H DC06V |
6 |
100 |
60 |
4.5 |
0.6 |
7.8 |
| HR703H DC09V |
9 |
225 |
40 |
6.75 |
0.9 |
11.7 |
| HR703H DC12V* |
12 |
400 |
30 |
9.00 |
1.2 |
15.6 |
| HR703H DC24V* |
24 |
1,600 |
15 |
18.00 |
2.4 |
31.2 |
| HR703H DC48V |
48 |
6,400 |
7.5 |
36.00 |
4.8 |
62.4 |
|
|
Note: All values in the chart are measured at 23¡É
|
|
|
|
|
|
 |
|