2Form A exclusive, 5A power relay
1.Economical version of HR-CR323
2.5mm shorter in length than HR-CR323
3.Conforms to various safety standard
4.Coil sensitivity avaliable in 530mW and 720mW
5.Sealed construction standard
1.Home appliance, Industrial control
To convert into inches, multiply by 0.03937
Copper-side view
Copper-side view
Contact data
Arrangement 2 Form A (DPST)
Contact material Ag Alloy
Initial contact resistance 100m§Ù max.
Rated load, resistive 5A 30VDC
5A 250VAC
Maximum switching current 5A
Maximum switching
capacity
with DC voltage:
with AC voltage:
150W
1,250VA
Minimum switching voltage 1) 30VDC
250VAC
Coil data
Nominal voltage 5VDC to 48VDC
Nominal power consumption 2) 530mW, 720mW
Operate voltage 3) 75% of nominal voltage
Release voltage 4) 10% of nominal voltage
2), 3), 4)The values depend on coil voltage, see Part selection chart
General data
Operate time 20ms max. at nominal voltage
Release time 10ms max. at nominal voltage
Initial insulation resistance 1,000 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
1,000VACrms for 1 minute
3,000VACrms for 1 minute
Surge strength Between contacts &
Between contacts & coil:
5,000V
Expected life Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated
load
Vibration
resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature £­40¡É to £«70¡É (with no icing)
Humidity 45% to 85% RH
Weight 13g approx.
Note: The above figures are initial values
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part number Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
)
Max
voltage
(VDC)
Nominal
power
(mW)
Standard coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3N DC05 5 35 144 3.75 0.5 6.5 720
HR-CR3N DC06 6 50 120 4.5 0.6 7.8
HR-CR3N DC09 9 112 80 6.75 0.9 11.7
HR-CR3N DC12 12 200 60 9.0 1.2 15.6
HR-CR3N DC18 18 450 40 13.5 1.8 23.4
HR-CR3N DC24 24 800 30 18.0 2.4 31.2
HR-CR3N DC48 48 3,200 15 36.0 4.8 62.4
Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3N DC05H 5 47 106 3.75 0.5 6.5 530
HR-CR3N DC06H 6 68 88 4.5 0.6 7.8
HR-CR3N DC09H 9 153 59 6.75 0.9 11.7
HR-CR3N DC12H 12 273 44 9.0 1.2 15.6
HR-CR3N DC18H 18 620 29 13.5 1.8 23.4
HR-CR3N DC24H 24 1,085 22.1 18.0 2.4 31.2
HR-CR3N DC48H 48 4,350 11.0 36.0 4.8 62.4
Note: All values in the chart are measured at 23¡É