| 2Form A exclusive, 5A power relay |
|
 |
1.Economical version of HR-CR323
2.5mm shorter in length than HR-CR323
3.Conforms to various safety standard
4.Coil sensitivity avaliable in 530mW and 720mW
5.Sealed construction standard
|
|
 |
|
1.Home appliance, Industrial control
|
|
 |
| To convert into inches, multiply by 0.03937 |
|
|
|
 |
Copper-side view
|
 |
Copper-side view
|
|
|
|
| Contact data |
| Arrangement |
2 Form A (DPST) |
| Contact material |
Ag Alloy |
| Initial contact resistance |
100m§Ù max. |
| Rated load, resistive |
5A 30VDC 5A 250VAC |
| Maximum switching current |
5A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
150W 1,250VA |
| Minimum switching voltage 1) |
30VDC 250VAC |
| Coil data |
| Nominal voltage |
5VDC to 48VDC |
| Nominal power consumption 2) |
530mW, 720mW |
| Operate voltage 3) |
75% of nominal voltage |
| Release voltage 4) |
10% of nominal voltage |
|
2), 3), 4)The values depend on coil voltage, see Part selection chart
|
|
| General data |
| Operate time |
20ms max. at nominal voltage |
| Release time |
10ms max. at nominal voltage |
| Initial insulation resistance |
1,000 M§Ù min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000VACrms for 1 minute 3,000VACrms for 1 minute |
| Surge strength |
Between contacts & Between contacts & coil: |
5,000V |
| Expected life |
Mechanical: Electrical: |
More than 10,000,000 operations More than 100,000 operations at rated load |
Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.5mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£40¡É to £«70¡É (with no icing) |
| Humidity |
45% to 85% RH |
| Weight |
13g approx. |
|
Note: The above figures are initial values
|
|
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC)) |
Max voltage (VDC) |
Nominal power (mW) |
| Standard coil 1 Form C, 1 Form A, 2 Form C, 2 Form A |
| HR-CR3N DC05 |
5 |
35 |
144 |
3.75 |
0.5 |
6.5 |
720 |
| HR-CR3N DC06 |
6 |
50 |
120 |
4.5 |
0.6 |
7.8 |
| HR-CR3N DC09 |
9 |
112 |
80 |
6.75 |
0.9 |
11.7 |
| HR-CR3N DC12 |
12 |
200 |
60 |
9.0 |
1.2 |
15.6 |
| HR-CR3N DC18 |
18 |
450 |
40 |
13.5 |
1.8 |
23.4 |
| HR-CR3N DC24 |
24 |
800 |
30 |
18.0 |
2.4 |
31.2 |
| HR-CR3N DC48 |
48 |
3,200 |
15 |
36.0 |
4.8 |
62.4 |
| Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A |
| HR-CR3N DC05H |
5 |
47 |
106 |
3.75 |
0.5 |
6.5 |
530 |
| HR-CR3N DC06H |
6 |
68 |
88 |
4.5 |
0.6 |
7.8 |
| HR-CR3N DC09H |
9 |
153 |
59 |
6.75 |
0.9 |
11.7 |
| HR-CR3N DC12H |
12 |
273 |
44 |
9.0 |
1.2 |
15.6 |
| HR-CR3N DC18H |
18 |
620 |
29 |
13.5 |
1.8 |
23.4 |
| HR-CR3N DC24H |
24 |
1,085 |
22.1 |
18.0 |
2.4 |
31.2 |
| HR-CR3N DC48H |
48 |
4,350 |
11.0 |
36.0 |
4.8 |
62.4 |
|
Note: All values in the chart are measured at 23¡É
|
|
|
|
|
|
 |
|