5A to 16A next generation general purpose power relay |
|
 |
1.4mm lower in height than HRCR3 series
2.Wide contact arrangements
1 Form A to 2 Form C
3.16A contact capacity
4.Sealed construction standard
|
|
 |
|
1.Home appliance, Industrial control
|
|
 |
| To convert into inches, multiply by 0.03937 |
|
|
|
 |
Copper-side view
|
 |
Copper-side view
|
|
|
|
2 Pole type
|
 |
| To convert into inches, multiply by 0.03937 |
 |
 |
Copper-side view
|
 |
Copper-side view
|
|
|
|
| Contact data |
| Arrangement |
1 Form A (SPST) to 2 Form C (DPDT) |
| Contact material |
Ag Alloy |
| Initial contact resistance |
100m§Ù max. |
| Type |
2 Pole type 2 Form A, C |
1 Pole type |
Standard 1 Form A, C |
K type |
| 1 Form C |
1 Form A |
| Rated load, resistive |
5A 30VDC 5A 250VAC TV-3 |
10A 30VDC 10A 250VAC TV-8 |
10A 30VDC 10A 250VAC |
16A 30VDC 16A 250VAC |
| Maximum switching current |
5A |
10A |
16A |
16A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
150W 1,250VA |
300W 2,500VA |
300W 2,500VA |
480W 3,840VA |
| Maximum switching voltage |
250VAC Resistive |
| Minimum switching rating1) |
100mA 5VDC |
|
1)Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental
conditions and expected reliability levels.
|
|
| Coil data |
| Nominal voltage |
5VDC to 48VDC |
| Nominal power consumption 2) |
530mW, 720mW |
| Operate voltage 3) |
80% of nominal voltage |
| Release voltage 4) |
10% of nominal voltage |
|
2), 3), 4)The values depend on coil voltage, see Part selection chart
|
|
| General data |
| Operate time |
15ms max. at nominal voltage |
| Release time |
5ms max. at nominal voltage |
| Initial insulation resistance |
1,000 M§Ù min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000VACrms for 1 minute 5,000VACrms for 1 minute |
| Expected life |
Mechanical: Electrical: |
More than 10,000,000 operations More than 100,000 operations at rated load |
Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.5mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£40¡É to £«70¡É (with no icing) |
| Humidity |
45% to 85% RH |
| Weight |
17g approx. |
|
Note: The above figures are initial values
|
Part number description |
|
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC)) |
Max voltage (VDC) |
Nominal power (mW) |
| Standard coil 1 Form C, 1 Form A, 2 Form C, 2 Form A |
| HR-CR3¡à¡à DC05¡à¡à |
5 |
35 |
144 |
4 |
0.5 |
6.5 |
720 |
| HR-CR3¡à¡à DC06¡à¡à |
6 |
50 |
120 |
4.8 |
0.6 |
7.8 |
| HR-CR3¡à¡à DC09¡à¡à |
9 |
112 |
80 |
7.2 |
0.9 |
11.7 |
| HR-CR3¡à¡à DC12¡à¡à |
12 |
200 |
60 |
9.6 |
1.2 |
15.6 |
| HR-CR3¡à¡à DC18¡à¡à |
18 |
450 |
40 |
14.4 |
1.8 |
23.4 |
| HR-CR3¡à¡à DC24¡à¡à |
24 |
800 |
30 |
19.2 |
2.4 |
31.2 |
| HR-CR3¡à¡à DC48¡à¡à |
48 |
3,200 |
15 |
38.4 |
4.8 |
62.4 |
| Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A |
| HR-CR3¡à¡à DC05¡à¡à H |
5 |
47 |
106 |
4 |
0.5 |
6.5 |
530 |
| HR-CR3¡à¡à DC06¡à¡à H |
6 |
68 |
88 |
4.8 |
0.6 |
7.8 |
| HR-CR3¡à¡à DC09¡à¡à H |
9 |
153 |
59 |
7.2 |
0.9 |
11.7 |
| HR-CR3¡à¡à DC12¡à¡à H |
12 |
273 |
44 |
9.6 |
1.2 |
15.6 |
| HR-CR3¡à¡à DC18¡à¡à H |
18 |
620 |
29 |
14.4 |
1.8 |
23.4 |
| HR-CR3¡à¡à DC24¡à¡à H |
24 |
1,085 |
22.1 |
19.2 |
2.4 |
31.2 |
| HR-CR3¡à¡à DC48¡à¡à H |
48 |
4,350 |
11.0 |
38.4 |
4.8 |
62.4 |
|
Note: All values in the chart are measured at 23¡É
|
|
|
|
|
 |
|