5A to 16A next generation general purpose
power relay
1.4mm lower in height than HRCR3 series
2.Wide contact arrangements
  1 Form A to 2 Form C
3.16A contact capacity
4.Sealed construction standard
1.Home appliance, Industrial control
To convert into inches, multiply by 0.03937
Copper-side view
Copper-side view

2 Pole type


To convert into inches, multiply by 0.03937
Copper-side view
Copper-side view
Contact data
Arrangement 1 Form A (SPST) to 2 Form C (DPDT)
Contact material Ag Alloy
Initial contact resistance 100m§Ù max.
Type 2 Pole type
2 Form A, C
1 Pole type
Standard
1 Form A, C
K type
1 Form C 1 Form A
Rated load, resistive 5A 30VDC
5A 250VAC
TV-3
10A 30VDC
10A
250VAC
TV-8
10A 30VDC
10A
250VAC
16A 30VDC
16A
250VAC
Maximum switching current 5A 10A 16A 16A
Maximum switching
capacity
with DC voltage:
with AC voltage:
150W
1,250VA
300W
2,500VA
300W
2,500VA
480W
3,840VA
Maximum switching voltage 250VAC Resistive
Minimum switching rating1) 100mA 5VDC
1)Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
Coil data
Nominal voltage 5VDC to 48VDC
Nominal power consumption 2) 530mW, 720mW
Operate voltage 3) 80% of nominal voltage
Release voltage 4) 10% of nominal voltage
2), 3), 4)The values depend on coil voltage, see Part selection chart
General data
Operate time 15ms max. at nominal voltage
Release time 5ms max. at nominal voltage
Initial insulation resistance 1,000 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
1,000VACrms for 1 minute
5,000VACrms for 1 minute
Expected life Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated
load
Vibration
resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature £­40¡É to £«70¡É (with no icing)
Humidity 45% to 85% RH
Weight 17g approx.
Note: The above figures are initial values
Part number description
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part number Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
)
Max
voltage
(VDC)
Nominal
power
(mW)
Standard coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3¡à¡à DC05¡à¡à 5 35 144 4 0.5 6.5 720
HR-CR3¡à¡à DC06¡à¡à 6 50 120 4.8 0.6 7.8
HR-CR3¡à¡à DC09¡à¡à 9 112 80 7.2 0.9 11.7
HR-CR3¡à¡à DC12¡à¡à 12 200 60 9.6 1.2 15.6
HR-CR3¡à¡à DC18¡à¡à 18 450 40 14.4 1.8 23.4
HR-CR3¡à¡à DC24¡à¡à 24 800 30 19.2 2.4 31.2
HR-CR3¡à¡à DC48¡à¡à 48 3,200 15 38.4 4.8 62.4
Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3¡à¡à DC05¡à¡à H 5 47 106 4 0.5 6.5 530
HR-CR3¡à¡à DC06¡à¡à H 6 68 88 4.8 0.6 7.8
HR-CR3¡à¡à DC09¡à¡à H 9 153 59 7.2 0.9 11.7
HR-CR3¡à¡à DC12¡à¡à H 12 273 44 9.6 1.2 15.6
HR-CR3¡à¡à DC18¡à¡à H 18 620 29 14.4 1.8 23.4
HR-CR3¡à¡à DC24¡à¡à H 24 1,085 22.1 19.2 2.4 31.2
HR-CR3¡à¡à DC48¡à¡à H 48 4,350 11.0 38.4 4.8 62.4
Note: All values in the chart are measured at 23¡É