1.Low power consumption, 150mW
2.1,500V Surge strength conforms to FCC part68
3.Basic grid (one inch) terminal layout
4.Immersion cleanable, sealed type
1.Process controls, Sequence controls data processing
Contact data
Arrangement 2 Form C (SPDT), 4 Form C (4PDT)
Contact material Ag Alloy
Initial contact resistance 50m¥Ø max.
Rated load, resistive 2 Form C 4 Form C
7A 30VDC
7A 250VAC
5A 30VDC
5A 250VAC
Maximum switching current 7A 5A
Maximum switching
capacity
with DC voltage:
with AC voltage:
210W
1,750VA
150W
1,200VA
Maximum switching voltage 125VDC
250VAC
Minimum switching rating 1) 100mA 5VDC
1) Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
Coil data
Nominal voltage 6VDC to 110VDC
6VAC to 240VAC
Nominal power consumption 2) DC Coil:
AC Coil:
0.9W to 1.1W approx.
0.9VA to 1.2VA (60Hz) approx.
Operate voltage 3) 80% of nominal voltage
Release voltage 4) DC Coil:
AC Coil:
10% of nominal voltage
30% of nominal voltage
2), 3), 4)The values depend on coil voltage, see Part selection chart
Contact data
Operate time 20ms max. at nominal voltage
Release time 20ms max. at nominal voltage
Initial insulation resistance 100 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
500VACrms for 1 minute
1,000VACrms for 1 minute
Expected life Mechanical:
Electrical:
More than 1,000,000 operations
More than 200,000 operations at rated load
Vibration resistance Functional:
Destructive:
10 ~ 55Hz dual amplitude: 1.5mm
10 ~ 55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature DC Coil:
AC Coil:
£­35¡É to £«55¡É(with no icing)
Humidity 35% to 80% RH
Weight 35g approx.
Note: The above figures are initial values
Part number description is provided for reference, part number can not be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part number Nominal
voltage
(V)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(V)
Must release
voltage
(V)
Max
voltage
(V)
Nominal
power
(W,VA)
50Hz 60Hz
DC Coil
HR705-¡à¡à¡à 6VDC 6 40 150 4.8 0.6 6.6 0.9
approx.
HR705-¡à¡à¡à 12VDC 12 160 75 9.6 1.2 13.2
HR705-¡à¡à¡à 24VDC 24 650 36.9 19.2 2.4 26.4
HR705-¡à¡à¡à 48VDC 48 2,600 18.5 38.4 4.8 52.8
HR705-¡à¡à¡à 100/110VDC 100/110 11,000 9.1/10 80/88 10/11 110/121 1.1 approx.
AC Coil
HR705-¡à¡à¡à 6VAC 6 12.2 214.1 183 4.8 1.8 6.6 1.0 to 1.2
(60Hz)
Approx.
HR705-¡à¡à¡à 12VAC 12 46 106.5 91 9.6 3.6 13.2
HR705-¡à¡à¡à 24VAC 24 180 53.8 46 19.2 7.2 26.4
HR705-¡à¡à¡à 48VAC 48 788 25.7 22 40.0 15.0 55.0
HR705-¡à¡à¡à 100/110VAC 100/110 3,750 11.7/12.9 10/11 80/88 30/33 110/121
0.9 to 1.2
(60Hz)
Approx.
HR705-¡à¡à¡à 110/120VAC 110/120 4,430 9.9/10.8 8.4/9.2 88/96 33/36 121/132
HR705-¡à¡à¡à 200/220VAC 200/220 12,950 6.2/6.8 5.3/5.8 160/176 60/66 220/242
HR705-¡à¡à¡à 220/240VAC 220/240 18,790 4.8/5.3 4.2/4.6 176/192 66/72 242/264