1.Sequence control to power applications
2.A wide range of variations and options available
3.Arc suppression barrier, 3 and 4 pole types
4.Conforms to various safety standard
1.Process controls, Sequence controls data processing
To convert into inches, multiply by 0.03937
Contact data
Arrangement 1 Form C (SPDT) to 4 Form C (4PDT)
Contact material AgCdO
Initial contact resistance 50m§Ù max.
Rated load, resistive 1,2,3 Form C 4 Form C
5A 24VDC
5A 240VAC
3A 24VDC
3A 240VAC
Maximum switching current 15A 3A
Maximum switching
capacity
with DC voltage:
with AC voltage:
210W
1,200VA
72W
720VA
Maximum switching voltage 125VDC
250VAC
Minimum switching rating 1) 100mA 5VDC
1) Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
Coil data
Nominal voltage 6VDC to 110VDC
6VAC to 240VAC
Nominal power consumption 2) DC Coil:
AC Coil:
0.9W approx.
0.9VA to 1.2VA (60Hz) approx.
Operate voltage 3) 80% of nominal voltage
Release voltage 4) DC Coil:
AC Coil:
10% of nominal voltage
30% of nominal voltage
2), 3), 4)The values depend on coil voltage, see Part selection chart
Contact data
Operate time 20ms max. at nominal voltage
Release time 20ms max. at nominal voltage
Initial insulation resistance 100 M§Ù min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
1,000Vrms for 1 minute
1,500Vrms for 1 minute
Expected life Mechanical:
Electrical:
More than 1,000,000 operations
More than 100,000 operations at rated load
Vibration resistance Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature DC Coil:
AC Coil:
£­35¡É¡­£«55¡É (with no icing)
Humidity 35% to 85% RH
Weight 33g approx.
Note: The above figures are initial values
Part number description is provided for reference, part number can not be arbitrarily composed.