1.Replaces HR707 series
2.10A 2 Form C (DPDT) 3 Form C (3PDT) configurations
3.Ruggedly constructed for long operating life
4.Dielectric strength 2,500V enhanced from 1,500V
of HR707 series
|
 |
|
1.Voltage or current monitoring
|
|
|
|
 |
| To convert into inches, multiply by 0.03937 |
| Contact data |
| Arrangement |
2 Form C, 3 Form C |
| Contact material |
AgCdO |
| Initial contact resistance |
50m§Ù max. |
| Rated load, resistive |
10A 28VDC 10A 250VAC |
| Maximum switching current |
10A |
Maximum switching capacity |
with DC voltage: with AC voltage: |
280W 2,500VA |
| Maximum switching voltage |
250VDC 250VAC |
| Minimum switching rating 1) |
100mA 5VDC |
|
1)
Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
|
|
| Coil data |
| Nominal voltage |
6VDC to 100VDC 6VAC to 240VAC |
| Nominal power consumption 2) |
DC Coil: AC Coil: |
1.3W to 1.6W approx. 2.1VA to 2.4VA (60Hz) approx |
| Operate voltage 3) |
80% of nominal voltage |
| Release voltage 4) |
DC Coil: AC Coil: |
10% of nominal voltage 30% of nominal voltage |
|
2), 3), 4)The values depend on coil voltage, see Part selection chart
|
|
| Contact data |
| Operate time |
DC Coil: AC Coil: |
25ms max. at nominal voltage 20ms max. at nominal voltage |
| Release time |
20ms max. at nominal voltage |
| Initial insulation resistance |
100 M§Ù min. (500VDC) |
| Dielectric strength |
Between open contacts: Between contacts & coil: |
1,000Vrms for 1 minute 1,500Vrms for 1 minute |
| Expected life |
Mechanical: Electrical: |
More than 10,000,000 operations More than 100,000 operations at rated load |
| Vibration resistance |
Functional: Destructive: |
10¡55Hz dual amplitude: 1.0mm 10¡55Hz dual amplitude: 1.5mm |
| Shock resistance |
Functional: Destructive: |
10G min. 100G min. |
| Ambient temperature |
£10¡É to £«40¡É (with no icing) |
| Humidity |
35% to 85% RH |
| Weight |
75g approx. |
|
Note: The above figures are initial values
|
|
|
Part number description is provided for reference, part number can not be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
|
|
| Part number |
Nominal voltage (VDC) |
Coil resistance (§Ù¡¾10%) |
Nominal current (mA) |
Must operate voltage (VDC) |
Must release voltage (VDC)) |
Max voltage (VDC) |
Nominal power (mW) |
| 50Hz |
60Hz |
| DC Coil |
| HR707N-¡à¡à¡à 6VDC |
6 |
23.5 |
225 |
4.8 |
0.6 |
6.6 |
1.3 to 1.6 approx. |
| HR707N-¡à¡à¡à 12VDC |
12 |
95 |
126 |
9.6 |
1.2 |
13.2 |
| HR707N-¡à¡à¡à 24VDC |
24 |
430 |
71 |
19.2 |
2.4 |
26.4 |
| HR707N-¡à¡à¡à 48VDC |
48 |
1,630 |
48 |
38.4 |
4.8 |
52.8 |
| HR707N-¡à¡à¡à 48VDC |
100 |
6,800 |
14.7 |
80.0 |
10 |
110 |
| AC Coil |
| HR707N-¡à¡à¡à 6VAC |
6 |
5.3 |
400 |
360 |
4.8 |
1.8 |
6.6 |
2.1 approx. (60Hz) |
| HR707N-¡à¡à¡à 12VAC |
12 |
21.5 |
198 |
180 |
9.6 |
3.6 |
13.2 |
| HR707N-¡à¡à¡à 24VAC |
24 |
91.0 |
97 |
88 |
19.2 |
7.2 |
26.4 |
| HR707N-¡à¡à¡à 48VAC |
48 |
420 |
42.6 |
40 |
38.4 |
14.4 |
52.8 |
| HR707N-¡à¡à¡à 100/110VAC |
100/110 |
1,620 |
22.4/24.7 |
19/21 |
80/88 |
30/33 |
110/121 |
2.4 approx. (60Hz) |
| HR707N-¡à¡à¡à 200/220VAC |
200/220 |
7,100 |
11.7/12.9 |
9.7/10.7 |
160/176 |
60/66 |
220/242 |
| HR707N-¡à¡à¡à 220/240VAC |
220/240 |
7,600 |
8/10 |
7/9 |
176/192 |
66/72 |
242/264 |
|
|
Note: All values in the chart are measured at 23¡É
|
|
|
 |
|