1.Designed for heavy inductive load application
2.2mm lower in height than HR-CR6 Series
3. High surge strength 10,000V
4. Characteristics deformation caused during Quick-connect placement and removal prevented by a built-in absorber
1.Home appliance, Motor, Heater
To convert into inches, multiply by 0.03937
Copper-side view
Copper-side view
Contact data
Arrangement 1 Form A (SPST)
Contact material Ag Alloy
Initial contact resistance 30m§Ù max.
Rated load, resistive 20A 125VAC, 16A 250VAC/30VDC
Maximum switching current 20A
Maximum switching capacity 4,000VA, 480W
Maximum switching voltage 30VDC / 250VAC
Coil data
Nominal voltage 5VDC to 48VDC
Nominal power consumption 1) 540mW
Operate voltage 2) 80% of nominal voltage
Release voltage 3) 10% of nominal voltage
1), 2), 3)The values depend on coil voltage, see Part selection chart
Contact data
Operate time 20ms max. at nominal voltage
Release time 10ms max. at nominal voltage
Initial insulation resistance 1,000 M min. (500VDC)
Dielectric strength Between open contacts:
Between contacts & coil:
1,000VACrms for 1 minute
4,500VACrms for 1minute
Surge strength Between contacts & coil: 10,000V
Expected life Mechanical:
Electrical:
More than 1,000,000 operations
More than 100,000 operations at rated load
Vibration resistance Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance Functional:
Destructive:
10G min.
100G min.
Ambient temperature -30¡É to +60¡É (with no icing)
Humidity 45% to 80% RH
Weight 15g approx.
Note: The above figures are initial values
Part number description is provided for reference, part number can not be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part number Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
)
Max
voltage
(VDC)
Nominal
power
(mW)
Quick-connect(#250) type
HR-CR6S DC05V 5 46.3 108 4.0 0.5 6.5 540
HR-CR6S DC06V 6 66.7 90 4.8 0.6 7.8
HR-CR6S DC09V 9 150 60 7.2 0.9 11.7
HR-CR6S DC12V 12 270 45 9.6 1.2 15.6
HR-CR6S DC24V 24 1,067 22.5 19.2 2.4 31.2
HR-CR6S DC48V 48 4,267 11.2 38.4 4.8 62.4
Quick-connect(#250) type
HR-CR6S DC05V 5 46.3 108 4.0 0.5 6.5 540
HR-CR6S DC06V 6 66.7 90 4.8 0.6 7.8
HR-CR6S DC09V 9 150 60 7.2 0.9 11.7
HR-CR6S DC12V 12 270 45 9.6 1.2 15.6
HR-CR6S DC24V 24 1,067 22.5 19.2 2.4 31.2
HR-CR6S DC48V 48 4,267 11.2 38.4 4.8 62.4
Note: All values in the chart are measured at 23¡É